Sun - Fri 8:00 - 18:00

General Information
Project Name Upper Seti I Hydroelectric Project
Name of River Seti
Nearest Town Pokhara
District / Development Region Kaski, Western Development Region
Type of power plant Run-of-River
Project Coordinates (Easting) 84° 56' 00" E to 84° 57'50" E
Project Coordinates (Northing) 28° 16' 38" N to 28° 18' 40" N
Construction Period 2.5 Years
Hydrology
Catchment area at intake site 334 km²
Long term annual average flow 28.41 m³/s
Design Discharge (Q45) 15.00 m³/s
Design flood at intake (1 in 100) 884.10 m³/s
Design Flood at Powerhouse (1 in 100) 1058.80 m³/s
Downstream release 0.64 m3/s
Infrastructure Components
Diversion weir type Permanent concrete weir (Ogee shape)
Diversion weir crest level 1089.5 gmsl
Diversion weir length 40.0 m
Diversion weir height 6.5 m from the Bed level
Sluice (number/width/height/slope) 1 / 2.5 m / 3.0 m / 1 in 10
Intake type Side Intake orifice type (3 openings of 3.0 m x 2.50 m)
Gravel trap dimensions 8.5 m (length) x 11.0 m (width)
Approach Canal dimensions 41 m (length) x 2.2 m (width) x 2.2 m (height)
Settling basin specifications 3 bays, 48.0 m length, 6.0 m width, 4.5 m depth, 0.2 mm particle trap
Headrace pipe specifications Steel, 2.5 m diameter, 4146 m length, 10-16 mm thickness
Surge Tank specifications Circular RCC, 8.0 m diameter, 25.0 m height
Penstock Pipe specifications Steel, 2.5 m diameter, 380.0 m length, 10-22 mm thickness
Powerhouse dimensions 30.0m x 15.0m x 17m
Turbine centerline 970.0 amsl
Tailrace length 88m
Switch Yard dimensions 30.0 m x 25.0m
Power Generation Equipment
Turbine type Francis (Horizontal Axis)
Number of turbine units 2
Turbine rated output 6840 KW each
Turbine rated speed 500 rpm
Turbine rated efficiency 90%
Discharge per turbine unit 7.5 m3/sec
Generator type Synchronous with brushless excitation
Generator rated capacity 7730 KVA each
Generator rated efficiency 96%
Generator power factor 0.85
Generator speed 500 rpm
Generator frequency 50Hz
Generation voltage 11 kV
Transformer type Single phase, Outdoor, Oil Immersed
Number of transformer units 3x1+1
Transformer rated capacity 5.67 MVA
Transformer efficiency 99%
Power Transmission
Transmission Line voltage 132KV single circuit line
Transmission Line length Approximately 20 Km
Transmission route From Power house site to Lekkuath Sub-station
Power and Energy Output
Gross Head 119.50 m
Net Head 103.31 m
Installed Capacity 13.00 MW
Dry season Energy (with outage) 30.05 GWh
Wet season Energy (with outage) 53.99 GWh
Total Energy output 84.04 GWh
Financial Evaluation
Internal rate of return (IRR) 14.28%
BC ratio 1.27
Return on Equity 19.07%